BYVBN - PYROMARK PAINT SERIES 1200, SPECIAL GRAY
- MSDS: BYVBN
- Manufacturer: BIG THREE INDUSTRIES INC TEMPIL DIV
- Product Name: PYROMARK PAINT SERIES 1200, SPECIAL GRAY
- National Stock Number: 8010-00N062584
Product Identification
Product ID:PYROMARK PAINT SERIES 1200, SPECIAL GRAY
MSDS Date:09/01/1989
FSC:8010
NIIN:00N062584
MSDS Number: BYVBN
Responsible Party
SOUTH PLAINFIELD, NJ 07080
US
Emergency Phone: 201-757-8300
Info Phone: 201-757-8300
Cage: 82682
Contractor
Telephone: 908-757-8300
Cage: 82682
Ingredients
ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE/SOLVENT)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 45%
OSHA PEL 350 PPM
ACGIH TLV: 350 PPM;450 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
PIGMENT; (REFRACTORY PIGMENT)
Fraction By Weight: 33%
OSHA PEL N/K
ACGIH TLV: N/K
SILICONE; (ALKYD RESIN)
Fraction By Weight: 20%
OSHA PEL N/K
ACGIH TLV: N/K
THICKENING AGENT; (THICKENERS)
Fraction By Weight: 2%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:VAPOR:ANESTHESIA, DEATH. LIQUID MAY BE
HARMFUL OR FATAL IF SWALLOWED. WHEN HEATED COATING SOLIDS MAY EMIT
FUMES OR VAPORS WHICH MAY BE HARMFUL IF INHALED. CHLOROCARBON
MATERIALS HAVE PRODUCED SENSITIZ ATION OF MYOCARDIUM TO EPINEPHRINE
IN LAB ANIMALS & COULD HAVE SIMILAR EFFECTS IN HUMANS. (EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:ADRENOMIMETICS (E.G., EPINEPHRINE) MAY
BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS
ACUTELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR. OBTAIN IMMEDIATE MEDICAL
ATTENTION. INGEST:DO NOT INDUCE VOMITING. OBTAIN IMMEDIATE MEDICAL
ATTENTION. EYE:FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINUTES. IF
IRRITATION OR PAIN PERSISTS OBTAIN MEDICAL ATTENTION.SKIN:WASH
W/SOAP & WATER. IF IRRITATION OR PAIN PERSISTS OBTAIN MEDICAL
ATTENTION.
Fire Fighting
Lower Limits:7.5%
Upper Limits:15%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE .
Accidental Release
Spill Release Procedures:ABSORB IN RAGS & DISCARD BY APPROVED
PROCEDURES IN COMPLIANCE W/FEDERAL, STATE & LOCAL LAWS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID CONTACT W/EYES, SKIN & CLOTHING.
USE W/ADEQUATE VENTILATION. DO NOT USE NEAR OPEN FLAMES.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV
RADIATION MAY CAUSE THE FORMATION OF HCL &/OR PHOSGENE .
Exposure Controls
Respiratory Protection:NOT REQUIRED W/ADEQUATE VENTILATION. NIOSH/MSHA
APPROVED RESPIRATORY PROTECTION REQUIRED IN ABSENCE OF PROPER
VENTILATION.
Ventilation:LOCAL EXHAUST.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:OBSERVE GOOD HYGIENIC PRACTICES.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
Boiling Pt:B.P. Text:165F,74C
Vapor Pres:100 @ 20C
Vapor Density:4.55
Spec Gravity:1.3 (H*2O=1)
Solubility in Water:0.07 G/100 G @ 25C.
Appearance and Odor:PAINT; CHLORINATED SOLVENT ODOR.
Percent Volatiles by Volume:45
Stability
Stability Indicator/Materials to Avoid:YES
ALUMINUM IS NOT ACCEPTABLE MATERIAL FOR STORAGE.
Hazardous Decomposition Products:HCL, PHOSGENE . IF HEATED TO
DECOMPOSITION MAY EMIT CARBON DIOXIDE, CARBON MONOXIDE OR OTHER
TOXIC COMPOUNDS.
Disposal
Waste Disposal Methods:STANDARD, OBSERVING ALL FEDERAL, STATE & LOCAL
LAWS CONCERNING HEALTH & ENVIRONMENT.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.